Quality Management

Reliablity Tests

No. Test Item Test Conditions Reference
1 High-Temperature Storage Temperature: 125℃±3℃
Time: 1000±12 Hours
MIL-STD-202 Method 108
2 Temperature Cycle Temperature 1: -55℃±3℃
Temperature 2: 125℃±3℃
Temperature change between T1 and T2 at the soonest
Run 1000 cycles, maintain T1 and T2 5 minutes each in one cycle
JESD22 Method JA-104
3 Solder Heat Resistance Pre-heat: 125℃ 60~120 Seconds
Solder Temperature: 260℃±5℃
Time: 30 Seconds
MIL-STD-202 Method 210
4 Drop Test 3 Times Free Fall from 150cm height to concrete floor IEC 68-2-32
5 High Temperature, High Humidity Storage Temperature: 85℃±5℃
Relative Humidity: 80%--85%
Time: 250Hours±12 Hours
MIL-STD-202 Method 103
6 Solderability Dip in Flux:5~10 seconds
Temperature: 245℃±5℃
Time: 10 Seconds
J-STD-002
7 Aging Temperature: 85℃±2℃
Time: 250Hours±12 Hours
MIL-STD-202 Method 103
8 Thermal Shock Temperature 1: -55℃±3℃
Temperature 2: 125℃±3℃
Temperature Change between T1 and T2: 5 Seconds
100 cycles, maintain T1 and T2 for 30 minutes each in one cycle
MIL-STD-202 Method 107
9 Vibration Frequency Range: 10Hz~2000Hz
Amplitude: 1.5mm or 20G
4 hours in each direction, a total of 12 hours 
MIL-STD-202 Method 204